ESM inspections, fire door checks and annual reports for Southbank apartment towers, offices and venues in the City of Melbourne, postcode 3006.
Southbank is a suburb of high-rise apartment towers and commercial buildings on the south bank of the Yarra. For essential safety measures that means large buildings with long lists of measures, owners corporations carrying the duty for common property, and a lot of residents whose daily habits affect fire doors and exits.
Where Southbank sits
The City of Melbourne’s community profile describes the Southbank neighbourhood as bounded by the Yarra River to the north, St Kilda Road to the east, and Dorcas Street, Kings Way and CityLink to the south, with a short western edge along Lorimer Street and Wurundjeri Way. That neighbourhood is within the City of Melbourne, so its municipal building surveyor is the council’s building team.
Housing is almost all high density
Census figures compiled by .id for the City of Melbourne show 98.5% of dwellings in the Southbank neighbourhood were high density in 2021: 17,121 dwellings, up from 11,176 in 2016. That growth of 5,945 high-density dwellings in five years is a lot of new towers, and a lot of new occupancy permits with maintenance schedules attached. See the Southbank dwelling type profile.
What a Southbank tower carries
A typical residential or mixed-use tower can hold measures from most parts of Schedule 8 of the Building Regulations 2018:
- sprinkler systems, fire hydrants with booster connections, hose reels and pump sets
- smoke detection, occupant warning and intercom systems
- smoke control and stair pressurisation
- emergency lifts and lift fire service controls
- standby power
- hundreds of emergency lights and exit signs
- fire-isolated stairs with fire doors on every level
- fire-rated or solid core entry doors to each apartment
- car park mechanical ventilation in basement levels
The servicing is spread across several licensed contractors. Hydrants, sprinklers and hose reels are fire protection work under the Plumbing Regulations 2018. Lighting repairs are electrical work. A separate ESM inspector, or the building manager, pulls it together for the owner to sign the annual report.
Typical Southbank problems
| Issue | Where it shows up | Service that covers it |
|---|---|---|
| Fire stair doors propped open | Stairs used between floors by residents or for moving in | Fire door inspections |
| Bikes, boxes and furniture in corridors and stairs | Move-in and move-out weeks, storage overflow | Exit and path of travel inspections |
| Failed fittings in car parks | Basement levels and open stairwells | Emergency and exit lighting testing |
| Replaced or altered unit entry doors | Renovated apartments | Fire door inspection and a note to the owners corporation |
| Records held by different contractors | Buildings that changed managers | ESM audit and log book setup |
Owners corporations and residents
In a subdivided tower the owners corporation normally carries the owner’s ESM duties for common property and engages the contractors, usually through its manager. Residents also count as occupiers for the parts they control, and every occupier must keep exits and paths of travel clear under regulation 228. Committees can only follow up a propped door or a blocked stair if the inspection report names the level and the door involved, so ask for that format.
The hydrant hydrostatic and booster test comes around every fifth year, so its year is known well in advance and can go into the owners corporation’s maintenance budget.
What it costs here
A published Melbourne cost guide works through a 45-level Southbank apartment tower and puts yearly servicing at $10,400 to $33,600 per year, before the annual report, which is quoted separately. The five-yearly hydrant booster test adds $1,500 to $5,000 per system per system in the year it falls due. More detail is in the Melbourne ESM cost guide, and the source is the What’s The Damage Melbourne fire compliance guide.
Next step
Lodge a Southbank enquiry with the building name or address, the number of levels and apartments, and your annual report anniversary if you know it. Your request reaches independent providers, who confirm access with the building manager and quote in their own name. Across the river, see the Melbourne CBD page.
Frequently asked questions
- Who signs the annual report for a Southbank apartment tower?
The owners corporation, as owner of the common property, normally signs through its manager or an authorised agent.
- Why do Southbank towers need several contractors?
Towers carry many different measures: sprinklers, hydrants, pumps, detection, warning systems, lifts and smoke control. Water-based systems need fire protection plumbers, lighting repairs need electricians, and lifts need lift technicians.
- Can residents be fined for blocking fire stairs?
Occupiers have a legal duty to keep exits and paths of travel clear, and penalties apply.
- How can we budget for the five-yearly hydrant test?
Ask your fire services contractor which year it is due and include it in the maintenance plan. Published Melbourne ranges for it appear on our cost guide page.